Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.024
Filtrar
1.
Medicine (Baltimore) ; 103(16): e37873, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38640309

RESUMO

RATIONALE: Wide neck bifurcation aneurysms (WNBA) are technically challenging for both surgical and endovascular treatments. Endovascular treatment for WNBA often requires dual antiplatelet therapy (DAPT) post stent insertion. Novel devices such as the pCONUS2 HPC neck bridging device have an HPC coating which reduces the device thrombogenicity. This theoretically allows for use of single antiplatelet therapy (SAPT), which would be advantageous, particularly in treating ruptured aneurysms. This case series aims to evaluate the safety of SAPT regimen only post stent insertion, by presenting our center early clinical experience in using pCONUS2 HPC neck bridging device in patients that are not suitable for DAPT. PATIENT CONCERNS: We report the cases of 3 patients (2 females, 1 male; range: 64-71 years old) who underwent coil embolization for WNBA using the pCONUS2 HPC device (2 unruptured WNBA, and 1 ruptured WNBA). As all 3 patients were allergic to Aspirin, they could only be started on SAPT post endovascular therapy. DIAGNOSIS: All 3 patients were diagnosed with WNBA on angiographic studies. Patient 1 had an unruptured left middle cerebral artery aneurysm; Patient 2 had a ruptured basilar tip aneurysm; Patient 3 had an unruptured anterior communicating artery (ACOM) aneurysm. INTERVENTIONS: All 3 WNBA were treated with pCONUS2 HPC neck bridging device. OUTCOMES: There were no immediate complications. The immediate angiographic result of aneurysm treatment in Patient 1 and Patient 2 demonstrated incomplete occlusions, with delayed complete occlusion of aneurysm in Patient 1 and growth of aneurysmal neck in Patient 2 on follow-up angiograms (range: 6-9 months). No major thrombo-embolic or hemorrhagic complications in the first 2 patients. For Patient 3, the immediate angiographic result of the treated aneurysm demonstrated complete occlusion. However, the patient readmitted 11 days post procedure with cerebral infarction, scoring 5 on the modified Rankin scale on discharge. LESSONS: pCONUS2 HPC as a neck bridging device in treating WNBA has yet to be shown superior to traditional techniques and devices. The theoretical advantage of HPC coating reducing its thrombogenicity requiring only SAPT is yet to be proven safe in clinical practice.


Assuntos
Aneurisma Roto , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Procedimentos Endovasculares/métodos , Aneurisma Intracraniano/terapia , Aneurisma Intracraniano/cirurgia , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/cirurgia , Embolização Terapêutica/métodos , Angiografia Cerebral , Estudos Retrospectivos , Stents
2.
Neurologia (Engl Ed) ; 39(4): 315-320, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38616058

RESUMO

PURPOSE: To investigate the effect of endovascular embolization of posterior communicating artery (Pcom) aneurysms on concomitant oculomotor nerve palsy (OMNP) and factors affecting the effect of treatment. MATERIALS AND METHODS: Patients with the Pcom aneurysms concomitant with OMNP were retrospectively enrolled for endovascular treatment of the aneurysms. All patients had the endovascular management. The clinical effect, degree of OMNP, size of the aneurysm, type of treatment, subarachnoid hemorrhage (SAH), and time from onset to treatment were analyzed on the resolution of OMNP. RESULTS: Ninety-six patients with 99 Pcom aneurysms were enrolled and treated endovascularly, with the success rate of 100%. Immediately after endovascular treatment, 75 aneurysms (75.75%) got complete occlusion, and 24 (24.24%) nearly complete occlusion. Followed up for 3-18 (mean 8.52±0.56) months, complete resolution of the OMNP was achieved in 63 patients (65.63%), partial resolution in 21 (21.88%), and non-recovery in the other 12 (12.50%). The degree of OMNP at onset, SAH, and time from onset to treatment were significantly (P<0.05) correlated with the resolution of OMNP. Univariate analysis revealed that younger age of the patient, degree of OMNP at onset, presence of subarachnoid hemorrhage, and time from disease onset to treatment were significantly (P<0.05) associated with the recovery of OMNP. Multivariate analysis revealed that the younger age, degree of OMNP at onset, and time from disease onset to treatment were significantly (P<0.05) associated with the recovery of OMNP. CONCLUSION: Endovascular embolization of Pcom aneurysms concomitant with OMNP can effectively improve the OMNP symptoms, especially for patients with moderate and a shorter history of OMNP. Younger age, degree of oculomotor nerve palsy at onset, and time from onset to treatment may significantly affect recovery of oculomotor nerve palsy.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Doenças do Nervo Oculomotor , Hemorragia Subaracnóidea , Humanos , Aneurisma Intracraniano/complicações , Aneurisma Intracraniano/terapia , Hemorragia Subaracnóidea/terapia , Estudos Retrospectivos , Doenças do Nervo Oculomotor/terapia
4.
AJNR Am J Neuroradiol ; 45(4): 418-423, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38453409

RESUMO

The Trenza embolization device is a frame coil implant with flow-disruption properties and is a new alternative to treat challenging mid-to-large-sized broad-neck bifurcation or sidewall aneurysms. We conducted an observational single-center retrospective study of 12 consecutive patients treated for 10 unruptured and 2 ruptured 6- to 12-mm broad-neck bifurcation or sidewall aneurysms with the Trenza device during 2022-2023. The median patient age was 64 years (interquartile range, 59-70 years), 58% were women, the median largest aneurysm diameter was 9.6 mm (interquartile range, 7.5-11.9 mm), the median dome-to-neck ratio was 1.8 (interquartile range, 1.6-1.9), the most common aneurysm locations were the anterior communicating artery (33%) and basilar artery tip (33%). After a median follow-up of 6.5 months, adequate aneurysm occlusion was achieved in 83%. There were 3 major ischemic complications (25%), leading to 2 permanent neurologic deficits (17%) and 1 transient neurologic deficit (8%). There was 1 fatal rupture of a treated aneurysm 1.6 months after the index treatment. Two patients were retreated (17%). Ischemic complications occurred in patients after a too-dense coil packing at the base of the aneurysm. No technical issues related to the device were encountered. In summary, an adequate aneurysm occlusion rate was achieved using the Trenza-assisted coiling technique for otherwise challenging mid-to-large-sized broad-neck aneurysms. Ischemic complications seemed to occur following overdense coiling at the base of the aneurysm.


Assuntos
Aneurisma Roto , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Aneurisma Intracraniano/complicações , Resultado do Tratamento , Estudos Retrospectivos , Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/terapia , Aneurisma Roto/complicações , Stents/efeitos adversos , Angiografia Cerebral/métodos
5.
Neuroradiology ; 66(5): 835-838, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38531984

RESUMO

Understanding the risks of contrast-induced encephalopathy (CIE), a serious complication of contrast agents, is crucial in endovascular treatment. We present the case of a 73-year-old woman who developed CIE in the medulla and cervical cord during coil embolization for unruptured left basilar-superior cerebellar artery and basilar artery tip aneurysms. The CIE was identified via neuromonitoring. In this case, spinal cord ischemia might have occurred due to reduced perfusion pressure after inserting the distal access catheter (DAC) in the vertebral artery. Multiple injections of contrast medium via the DAC during coil embolization likely contributed to an unusual form of CIE. Extreme caution is warranted during endovascular treatments involving the posterior circulation, due to the relatively high incidence of contrast-mediated encephalopathy, which can lead to severe consequences such as perforator infarction. Neuromonitoring is very useful for the early detection of neurological changes, particularly because intraoperative angiography may not reveal all irregularities.


Assuntos
Encefalopatias , Medula Cervical , Embolização Terapêutica , Aneurisma Intracraniano , Feminino , Humanos , Idoso , Resultado do Tratamento , Aneurisma Intracraniano/terapia , Aneurisma Intracraniano/cirurgia
6.
Rinsho Ketsueki ; 65(2): 84-89, 2024.
Artigo em Japonês | MEDLINE | ID: mdl-38448003

RESUMO

A 63-year-old man with adult T-cell leukemia-lymphoma underwent allogeneic bone marrow transplantation from an HLA-matched unrelated donor. On day 17 after transplantation, chest computed tomography (CT) showed nodules in the lower lobes of both lungs, and invasive pulmonary aspergillosis (IPA) was suspected. Treatment with liposomal amphotericin B was started, and improvement of infectious lesions was confirmed with CT on day 28. The antifungal agent was changed to voriconazole on day 52 because of progressive renal dysfunction. Disorders of consciousness and paralysis of the left upper and lower extremities developed on day 61. Brain CT showed subcortical hemorrhage in the right parietal and occipital lobes, and the patient died on day 62. An autopsy revealed filamentous fungi, suspected to be Aspergillus, in the pulmonary nodules and a ruptured cerebral aneurysm. Although IPA occurs in 10% of transplant recipients, vigilant monitoring for mycotic cerebral aneurysms is required to prevent hematogenous dissemination of Aspergillus, which is associated with a high mortality rate.


Assuntos
Transplante de Células-Tronco Hematopoéticas , Aneurisma Intracraniano , Leucemia-Linfoma de Células T do Adulto , Linfoma , Adulto , Masculino , Humanos , Pessoa de Meia-Idade , Aneurisma Intracraniano/complicações , Aneurisma Intracraniano/terapia , Leucemia-Linfoma de Células T do Adulto/complicações , Leucemia-Linfoma de Células T do Adulto/terapia , Transplante de Medula Óssea
7.
Neurosurg Rev ; 47(1): 100, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38427140

RESUMO

The comparability of endovascular coiling over neurosurgical clipping has not been firmly established in elderly patients with aneurysmal subarachnoid haemorrhage (aSAH). Data were obtained from all patients with aSAH aged ≥60 across three tertiary hospitals in Singapore from 2014 to 2019. Outcome measures included modified Rankin Scale (mRS) score at 3 and at 6 months, and in-hospital mortality. Of the 134 patients analyzed, 84 (62.7%) underwent coiling and 50 (37.3%) underwent clipping. The endovascular group showed a higher incidence of good mRS score 0-2 at 3 months (OR = 2.45 [95%CI:1.16-5.20];p = 0.018), and a lower incidence of in-hospital mortality (OR = 0.31 [95%CI:0.10-0.91];p = 0.026). There were no significant difference between the two treatment groups in terms of good mRS score at 6 months (OR = 1.98 [95%CI:0.97-4.04];p = 0.060). There were no significant differences in the incidence of complications, such as aneurysm rebleed, delayed hydrocephalus, delayed ischemic neurological deficit and venous thromboembolism between the two treatment groups. However, fewer patients in the coiling group developed large infarcts requiring decompressive craniectomy (OR = 0.32 [95%CI:0.12-0.90];p = 0.025). Age, admission WFNS score I-III, and coiling were independent predictors of good functional outcomes at 3 months. Only age and admission WFNS score I-III remained significant predictors of good functional outcomes at 6 months. Endovascular coiling, compared with neurosurgical clipping, is associated with significantly better short term outcomes in carefully selected elderly patients with aSAH. Maximal intervention is recommended for aSAH in the young elderly age group and those with favorable WFNS scores.


Assuntos
Aneurisma Roto , Procedimentos Endovasculares , Aneurisma Intracraniano , Hemorragia Subaracnóidea , Humanos , Pessoa de Meia-Idade , Aneurisma Roto/cirurgia , Estudos de Coortes , Aneurisma Intracraniano/terapia , Procedimentos Neurocirúrgicos , Hemorragia Subaracnóidea/complicações , Resultado do Tratamento
8.
Cesk Slov Oftalmol ; 80(1): 42-51, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38365581

RESUMO

PURPOSE: Intracranial aneurysms and their hemorrhagic and thromboembolic complications represent a serious nosological unit that significantly endangers those afflicted. They are mostly asymptomatic until rupture occurs. In two case reports, we present our observations of young patients with impaired vision and headaches, in whom we found the presence of intracranial aneurysms. OBSERVATIONS: Presentation of two case reports of patients who came to our department with impaired vision and headaches. The patients underwent a complete eye examination at our center, including a visual field examination. Based on the results of the examination, they were referred for  an imaging examination of the brain, which revealed the presence of intracranial aneurysms. The patients were subsequently sent to the interventional neuroradiology center, where they underwent a noninvasive endovascular neuroembolization procedure with flow diverter implantation. We continued to monitor the patients after the procedure and document the examination results up to 1 year after the procedure. CONCLUSIONS AND SIGNIFICANCE: Thanks to the fast detection, diagnosis, and management of both patients, we prevented the occurrence of aneurysm rupture, thus a life-threatening complication. After endovascular procedures with flow diverter implantation, we observed a significant improvement in visual acuity as well as perimetric findings in both patients. When intracranial aneurysms are found within a week of the onset of eye symptoms and treated within three months, defects in the visual fields improved in our two patients within 6-12 months, and in one of the two patients the defects almost completely disappeared.


Assuntos
Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/complicações , Aneurisma Intracraniano/terapia , Campos Visuais , Stents/efeitos adversos , Resultado do Tratamento , Estudos Retrospectivos , Transtornos da Visão/etiologia , Cefaleia/complicações
9.
Ann Biomed Eng ; 52(5): 1403-1414, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38402315

RESUMO

During follow-up of patients treated with WEB devices, shape changes have been observed. The quantitative three-dimensional measurement of the WEB shape modification (WSM) would offer useful information to be studied in association with the anatomical results and try to better understand mechanisms implicated in this modification phenomenon. We present a methodology to quantify the morphology and position of the WEB device in relation to the vascular anatomy. Three-dimensional rotational angiography (3DRA) images of seven aneurysms patients treated with WEBs were used, which also accompanied by a post-treatment 3DRA image and a follow-up 3DRA image. The device was manually segmented, obtaining the 3D models after treatment and at the follow-up. Volume, surface area, height, maximum diameter and WSM ratio of both surfaces were calculated. Position changes were evaluated measuring WEB axis and relative position between post-treatment and follow-up. Changes in WEB volume and surface area were observed with a mean modification of - 5.04 % ( ± 14.19 ) and - 1.68 % ( ± 8.29 ) , respectively. The positional variables also showed differences, mean change of device axis direction was 26.25 % ( ± 24.09 ) and mean change of distance l b was 5.87 % ( ± 10.59 ) . Inter-observer and intra-observer variability analyses did not show differences (ANOVA p > 0.05 ). This methodology allows quantifying the morphological and position changes suffered by the WEB device after treatment, offering new information to be studied in relation to the occurrence of WEB shape modification.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Variações Dependentes do Observador , Resultado do Tratamento , Estudos Retrospectivos , Angiografia Cerebral/métodos
10.
Neurosurg Rev ; 47(1): 74, 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38315259

RESUMO

Few studies have explored the effect of a flow-diverter device (FD) on blood flow in the A1 segment of the anterior cerebral artery (ACA), after treatment of intracranial aneurysms in the bifurcation region of the internal carotid artery (ICA). The main objective of this article is to investigate the factors that affect A1 blood flow after FD covers the A1 artery. This is a single-center, retrospective study. Data were collected retrospectively from our center, and patients whose FDs were placed for treatment from the terminal of the ICA to the M1 segment were analyzed. A total of 42 patients were included in the study. Immediate post-procedural angiography following device placement revealed decreased blood flow in the A1 of 15 (35.7%) patients and complete occlusion of the A1 segment in 11 (26.2%) patients. During an average follow-up period of 9.8 months, the A1 segment was ultimately occluded in 25 patients (59.5%) and decreased blood flow in 4 patients (9.5%). When using FD to cover the A1 artery for the treatment of intracranial aneurysms, patients with preoperative opening of the anterior communicating artery (AcomA) are more prone to occlusion or decreased blood flow of the A1 artery, compared to patients without opening.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Humanos , Artéria Cerebral Anterior/cirurgia , Estudos Retrospectivos , Aneurisma Intracraniano/terapia , Resultado do Tratamento , Hemodinâmica , Stents
11.
Prague Med Rep ; 125(1): 15-33, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38380451

RESUMO

Endovascular treatment is widely applied as the first-line treatment for intracranial aneurysms and includes simple coiling (SC), stent-assisted coiling (SAC), flow diversion stent, and flow disruption stent. The present study is a retrospective cohort study performed in Imam Khomeini Hospital, Department of Neurovascular Intervention, between March 2016 and March 2021. A total number of 229 patients with intracranial aneurysms who underwent therapeutic intravascular interventions were enrolled, of which 89 were treated with SC, 111 with SAC, 25 with flow diversion stent, and 4 with flow disruption stent. The mean age of the subjects was 51.8±12.6 years, and 51.1% were male. Modified Raymond-Roy classification (MRRC) was used to define the occlusion outcome. The success rate, considered as Class I and Class II of MRRC at treatment time was 89% (94.4% in SC, and 84.7% in SAC), which was increased to 90.9% (94% in SC, 93% in SAC, 69.6% in flow diversion stenting, 100% in flow disruption) at 6-month follow-up, and 84.6% (80.8% in SC, 87.8% in SAC, 78.3% in flow diversion stenting, and 100% in flow disruption) at 12-month follow-up. The mean modified Rankin Scale (mRS) before the procedure was 0.05±0.26 which was increased to 0.22±0.76 after the procedure, 0.22±0.76 at 6 months, and 0.30±0.95 at 12 months (P<0.001). Similar to previous studies, the present study demonstrates that neurovascular intervention can treat ruptured aneurysms as the first therapeutic modality with favourable outcomes. A double-blind, randomized clinical trial is needed to eliminate the confounding factors and better demonstrate the outcome.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos , Aneurisma Intracraniano/terapia , Estudos Retrospectivos , Stents , Resultado do Tratamento
12.
Sci Robot ; 9(87): eadh2479, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38381840

RESUMO

Cerebral aneurysms and brain tumors are leading life-threatening diseases worldwide. By deliberately occluding the target lesion to reduce the blood supply, embolization has been widely used clinically to treat cerebral aneurysms and brain tumors. Conventional embolization is usually performed by threading a catheter through blood vessels to the target lesion, which is often limited by the poor steerability of the catheter in complex neurovascular networks, especially in submillimeter regions. Here, we propose magnetic soft microfiberbots with high steerability, reliable maneuverability, and multimodal shape reconfigurability to perform robotic embolization in submillimeter regions via a remote, untethered, and magnetically controllable manner. Magnetic soft microfiberbots were fabricated by thermal drawing magnetic soft composite into microfibers, followed by magnetizing and molding procedures to endow a helical magnetic polarity. By controlling magnetic fields, magnetic soft microfiberbots exhibit reversible elongated/aggregated shape morphing and helical propulsion in flow conditions, allowing for controllable navigation through complex vasculature and robotic embolization in submillimeter regions. We performed in vitro embolization of aneurysm and tumor in neurovascular phantoms and in vivo embolization of a rabbit femoral artery model under real-time fluoroscopy. These studies demonstrate the potential clinical value of our work, paving the way for a robotic embolization scheme in robotic settings.


Assuntos
Neoplasias Encefálicas , Aneurisma Intracraniano , Procedimentos Cirúrgicos Robóticos , Robótica , Animais , Coelhos , Procedimentos Cirúrgicos Robóticos/métodos , Aneurisma Intracraniano/terapia , Fenômenos Magnéticos
13.
World Neurosurg ; 184: e166-e177, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38246531

RESUMO

BACKGROUND: Recanalization poses challenges after coil embolization in cerebral aneurysms. Establishing predictive models for postembolization recanalization is important for clinical decision making. However, conventional statistical and machine learning (ML) models may overlook critical parameters during the initial selection process. METHODS: In this study, we automated the identification of significant hemodynamic parameters using a PointNet-based deep neural network (DNN), leveraging their three-dimensional spatial features. Further feature analysis was conducted using saliency mapping, an explainable artificial intelligence (XAI) technique. The study encompassed the analysis of velocity, pressure, and wall shear stress in both precoiling and postcoiling models derived from computational fluid dynamics simulations for 58 aneurysms. RESULTS: Velocity was identified as the most pivotal parameter, supported by the lowest P value from statistical analysis and the highest area under the receiver operating characteristic curves/precision-recall curves values from the DNN model. Moreover, visual XAI analysis showed that robust injection flow zones, with notable impingement points in precoiling models, as well as pronounced interplay between flow dynamics and the coiling plane, were important three-dimensional features in identifying the recanalized aneurysms. CONCLUSIONS: The combination of DNN and XAI was found to be an accurate and explainable approach not only at predicting postembolization recanalization but also at discovering unknown features in the future.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Humanos , Inteligência Artificial , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Embolização Terapêutica/métodos , Hemodinâmica , Prótese Vascular
14.
J Neuroradiol ; 51(2): 224-229, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38262518

RESUMO

The increasing use of embolization devices with suboptimal radio-opacity to treat intracranial aneurysm underscores the need for advanced imaging techniques to characterize device-vessel interactions more accurately. Contrast-diluted cone-beam CT is commonly used in neurointervention but requires additional technical refinements to improve endovascular treatment assessment. In this technical note, we describe the virtual dilution cone beam CT (VDCBCT), a technique that synthetizes non-contrast and contrast-enhanced CBCT images to virtually dilute iodinated contrast agents, thereby facilitating a more accurate assessment of embolization device apposition. Through a set of intracranial aneurysms treated with different embolization devices, we describe the VDCBCT protocol and its usefulness for device apposition confidence. VDCBCT may enhance the global understanding of neurovascular embolization treatments by providing improved visualization of target vessels and low-radio-opacity embolization devices, obviating the need for contrast dilution.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Tomografia Computadorizada de Feixe Cônico/métodos , Meios de Contraste , Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos , Resultado do Tratamento
15.
Neuroradiology ; 66(3): 427-429, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38212489

RESUMO

This report examines delayed leukoencephalopathy as a postoperative complication after the use of flow diverter (FD) devices for endovascular cerebral aneurysm treatment. A case involving a 78-year-old female treated with a pipeline embolization device for a left internal carotid artery aneurysm is presented. Despite adherence to dual anti-platelet therapy, the patient developed intermittent headaches and memory issues 3 months post-operation. MRI revealed T1-enhancing foci and T2 hyperintense signal abnormalities in the left cerebral hemisphere, without new ischemic lesions, indicating potential embolic events or foreign body reactions. Following aphasia, a change from clopidogrel to prasugrel and the initiation of steroid pulse therapy led to the resolution of symptoms and MRI abnormalities over 6 months. This case underscores the reversibility of delayed leukoencephalopathy with appropriate intervention.


Assuntos
Doenças das Artérias Carótidas , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Feminino , Humanos , Idoso , Aneurisma Intracraniano/terapia , Aneurisma Intracraniano/cirurgia , Embolização Terapêutica/efeitos adversos , Stents/efeitos adversos , Doenças das Artérias Carótidas/terapia , Imageamento por Ressonância Magnética , Resultado do Tratamento
16.
Acta Neurochir (Wien) ; 166(1): 2, 2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-38200390

RESUMO

BACKGROUND AND PURPOSE: Pipeline embolization device (PED) is widely used in intracranial aneurysms, and the scope of applications for the PED, which is frequently used to treat cerebral aneurysms, is also growing. It has some effect on branching vessels as a result of its inherent properties. The effects of PED on the complications rate and branching vessels blockage have not yet been thoroughly investigated. OBJECTIVE: We conducted a systematic review searching reports from multiple databases on PED use for intracranial aneurysms, and analyzed the influence of PED on the occlusion rate of different branching vessels, and the influence of the amount of PED on the occlusion rate of branching vessels by meta-analysis. METHODS: We searched the literature using PUBMED, Web of Science, and OVID databases until August 2023. Inclusion criteria were that the study used only PED, included at least 10 patients, and recorded branching vessels occlusion rates, mortality, and neurological complications. RESULTS: Nine studies were analyzed consisting of 706 patients with 986 side branches. The results of the meta-analysis showed that application of more than one PED did not significantly elevate the rate of branching vessels occlusion compared to application of one PED (OR = 0.70; 95% CI: 0.34 to 1.43; P = 0.33). In the comparison of branching vessels occlusion rates in the anterior circulation, the anterior cerebral artery (ACA) had a significantly higher occlusion rate compared to the ophthalmic artery (OphA) (OR = 6.54; 95% CI: 3.05 to 14.01; P < 0.01), ACA also had a higher occlusion rate compared to the anterior choroidal artery (AchA) (OR = 15.44; 95% CI: 4.11 to 57.94 P < 0.01), ACA versus posterior communicating artery (PcomA) occlusion rate difference was not statistically significant (OR = 2.58; 95% CI: 0.63 to 12.82; P = 0.17), OphA versus AchA occlusion rate difference was not statistically significant (OR = 2.56; 95% CI: 0.89 to 7.38; P = 0.08), and the occlusion rate was significantly higher for PcomA compared to AchA (OR = 7.22; 95% CI: 2.49 to 20.95; P < 0.01) and lower for OphA compared to PcomA (OR = 0.33; 95% CI: 0.19 to 0.55; P < 0.01). CONCLUSION: The meta-analysis shows that use of multiple PEDs did not significantly increase the occlusion rate of branching vessels, and the larger the diameter of branching vessels covered by PED, the higher the occlusion rate of branching vessels. However, the incidence of complications is low after branching vessels occlusion in anterior circulation, which is related to the collateral circulation compensation of the branching vessels.


Assuntos
Aneurisma Intracraniano , Doenças Vasculares , Humanos , Aneurisma Intracraniano/terapia , Circulação Colateral , Artéria Cerebral Anterior , Prótese Vascular
17.
J Stroke Cerebrovasc Dis ; 33(3): 107582, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38237811

RESUMO

BACKGROUND: Aplastic or twig-like middle cerebral artery (Ap/T-MCA) is a rare vascular anomaly that can cause hemorrhagic and ischemic stroke. Ap/T-MCA can induce aneurysms due to the fragility of the vessel wall, consequently leading to subarachnoid hemorrhage. Herein, we report a case of Ap/T-MCA with subarachnoid hemorrhage without an aneurysm. CASE PRESENTATION: A 67-year-old man presented to our hospital with a sudden onset of headache. Computed tomography of the head revealed subarachnoid hemorrhage (SAH) in the left Sylvian fissure; however, no aneurysm was observed on digital subtraction angiography. Following conservative treatment, follow-up imaging showed no aneurysm or no recurrent stroke. CONCLUSION: Non-aneurysmal SAH is a possible indication of vessel wall fragility in Ap/T-MCA; however, a standardized treatment strategy for this condition remains to be established.


Assuntos
Aneurisma Roto , Aneurisma Intracraniano , Hemorragia Subaracnóidea , Humanos , Masculino , Idoso , Hemorragia Subaracnóidea/diagnóstico por imagem , Hemorragia Subaracnóidea/etiologia , Hemorragia Subaracnóidea/terapia , Artéria Cerebral Média/diagnóstico por imagem , Artéria Cerebral Média/anormalidades , Aneurisma Intracraniano/complicações , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Angiografia Cerebral/métodos , Tomografia Computadorizada por Raios X/métodos
18.
J Neurointerv Surg ; 16(3): 226-227, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38171612

RESUMO

Recurrent intracranial aneurysms (IAs) often present with more complex morphology such as irregular shape, shallow height, and wide neck, which can make for challenging endovascular treatments.1 Initial rupture and interventions are associated with fibrotic changes and considerable alteration in the aneurysm configuration, which limits retreatment options and increases the risk of complications during retreatment.2 The Woven Endobridge (WEB) embolization device has demonstrated high efficacy, flexibility, and safety for the treatment of wide-neck bifurcation IAs, including ruptured and recurrent IAs, as shown in multiple retrospective studies and meta-analyses.3-8 Due to its optimal barrel shape, the WEB device is useful in the setting of previously treated aneurysms, particularly with wide-neck previously coiled aneurysms.1 9 10 In this technical video of four cases (video 1), we describe the technical nuances of WEB embolization for recurrent IAs, which were initially either coiled or clipped and demonstrated progressive growth with a wide-neck presentation on follow-up. neurintsurg;16/3/226/V1F1V1Video 1Management of recurrent intracranial aneurysms via WEB: This video describes four recurrent intracranial aneurysms, which were initially either coiled or clipped but demonstrated progressive growth with a wide-neck presentation on follow-up. All cases were successfully treated via WEB.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Resultado do Tratamento , Estudos Retrospectivos
19.
J Stroke Cerebrovasc Dis ; 33(4): 107586, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38242183

RESUMO

OBJECTIVE: The off-label utilization of the Pipeline Embolization Device (PED) is a common practice in numerous medical centers globally. Therefore, we conducted a systematic review and meta-analysis to evaluate the overall outcomes of this off-label usage of PEDs. METHODS: PubMed, Web of Science, Ovid Medline, Ovid Embase, and Scopus were searched up to February 2023 using the Nested Knowledge platform to identify studies assessing the off-label use of PEDs. Any use of PED outside of the FDA-approved indication granted in 2018 is considered off-label use. Overall angiographic occlusion rates, ischemic and hemorrhagic complications, mortality, retreatment rates, and favorable clinic outcomes were included. Statistical analyses were performed to compare the overall outcome rates of anterior cerebral artery(ACA) vs. middle cerebral artery(MCA) and anterior vs posterior circulation subgroups. RESULTS: We included 26 studies involving a total of 1,408 patients. The overall rate of complete occlusion was 80.3 % (95 % CI= 76.0-84.1). Subgroup analysis demonstrated a statistically significant difference in the rate of complete occlusion between anterior circulation (78.9 %) and posterior circulation (69.2 %) (p value=0.02). The rate of good clinical outcomes was 92.8 % (95 % CI= 88.8-95.4). The mortality rate was 1.4 % (95 % CI= 0.5-2.7). The overall rate of ischemic complications was 9.5 % (95 % CI= 7.7-11.6), with a comparable difference between anterior circulation (7.7 %) and posterior circulation (12.8 %) (p value=0.07). There was no statistically significant difference in MCA vs ACA subgroups in all parameters. CONCLUSIONS: Off-label use of PEDs can be a safe and effective treatment option for intracranial aneurysms. However, there is a need for more prospective, high-quality, non-industry-funded registry studies and randomized trials to test the efficacy and safety of off-label usage of PEDs and to expand its indications.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Humanos , Uso Off-Label , Estudos Prospectivos , Estudos Retrospectivos , Embolização Terapêutica/efeitos adversos , Resultado do Tratamento , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Seguimentos
20.
J Neurointerv Surg ; 16(2): 177-182, 2024 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-37080769

RESUMO

BACKGROUND: This study aimed to evaluate the efficacy, stability, and safety of computer-assisted microcatheter shaping (CAMS) in patients with intracranial aneurysms. METHODS: A total of 201 patients with intracranial aneurysms receiving endovascular coiling therapy were continuously recruited and randomly assigned to the CAMS and manual microcatheter shaping (MMS) groups. The investigated outcomes included the first-trial success rate, time to position the microcatheter in aneurysms, rate of successful microcatheter placement within 5 min, delivery times, microcatheter stability, and delivery performance. RESULTS: The rates of first-trial success (96.0% vs 66.0%, P<0.001), successful microcatheter placement within 5 min (96.04% vs 72.00%, P<0.001), microcatheter stability (97.03% vs 84.00%, P=0.002), and 'excellent' delivery performance (45.54% vs 24.00%, P<0.001) in the CAMS group were significantly higher than those in the MMS group. Additionally, the total microcatheter delivery and positioning time (1.05 minutes (0.26) vs 1.53 minutes (1.00)) was significantly shorter in the CAMS group than in the MMS group (P<0.001). Computer assistance (OR 14.464; 95% CI 4.733 to 44.207; P<0.001) and inflow angle (OR 1.014; 95% CI 1.002 to 1.025; P=0.021) were independent predictors of the first-trial success rate. CAMS could decrease the time of microcatheter position compared with MMS, whether for junior or senior surgeons (P<0.001). Moreover, computer assistance technology may be more helpful in treating aneurysms with acute angles (p<0.001). CONCLUSIONS: The use of computer-assisted procedures can enhance the efficacy, stability, and safety of surgical plans for coiling intracranial aneurysms.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/terapia , Aneurisma Intracraniano/cirurgia , Embolização Terapêutica/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...